top of page

"Shower of Sparks"

Starting vibrators, available in 12 and 24 volt models, eliminate the need for impulse couplings used on many magnetos.

 The vibrator provides interrupted battery voltage to the magneto primary coil. This pulsating DC voltage is stepped up by the transformer action, producing a shower of sparks at the spark plug for improved starting.                   CMI Master Service Manual X43003, 3-3

Starting Vibrator Application

*

*Part numbers 10-357487-241, 10-357487-242, and 10-357808-24 are 24 volt vibrators which incorporate a balance coil and insulated vibrator coil.

bottom of page